Mason Archival Repository Service

Nanotechnology Enhanced Immunoassay for Preeclampsia

Show simple item record

dc.contributor.advisor Luchini, Alessandra
dc.contributor.author Zaidi, Syeda Fatima A.
dc.creator Zaidi, Syeda Fatima A.
dc.date 2013-12-06
dc.date.accessioned 2014-03-09T14:04:14Z
dc.date.available 2014-03-09T14:04:14Z
dc.date.issued 2014-03-09
dc.identifier.uri https://hdl.handle.net/1920/8650
dc.description.abstract N-isopropylacrylamide (NIPAm)-based, bait-loaded hydrogel particles are successfully used to capture, sequester and protect from enzymatic degradation low abundance, low molecular weight labile proteins in body fluids. In current protocols, proteins captured by the nanoparticles are eluted with chemical buffers and analyzed with immunoassays or mass spectrometry techniques. Here, a novel, in situ ELISA is presented in which captured proteins are probed with a labeling antibody directly inside the nanoparticles without the need of chemical elution. Dually crosslinked (degradable N,N’-(1,2-Dih ydroxyethylene)- bisacrylamide [DHEA] and nondegradable N,N′-methylenebis(acrylamide) BIS] crosslinkers) NIPAm particles functionalized with trypan blue were used. DHEA can be degraded by an oxidizing agent (e.g. NaIO4) thus increasing the pore size of the hydrogel nanoparticles and allowing the antibody to access the antigen previously trapped in the nanoparticle. Interleukin 6 (IL6) was chosen as a model molecule to test the nanoparticle based ELISA. IL-6 is a protein associated with preeclampsia, an autoimmune, hypertensive pregnancy-related medical problem that can lead to serious complications that can be life threatening to mother and child. Dually crosslinked NIPAm particles efficiently sequestered IL6 from human urine. Oxidative degradation of DHEA crosslinker by NaIO4, caused a partial erosion of the DHEA crosslinker resulting in loose network of hydrogel polymer and increased access of antibody to the captured IL6 protein. Captured IL6 was preserved from oxidative degradation by virtue of the interaction between the protein and trypan blue chemical bait. The IL6 ELISA, based on these dually cross linked NIPAm particles, showed a limit of detection of 600 picograms and two orders of magnitude dynamic range. Coefficient of variations was constantly below 5%. Sensitivity of the test can be improved by increasing the volume of urine processed. It is anticipated that this technology can be successfully used to detect true positive preeclamptic patients from a group of gestational hypertensive population.
dc.language.iso en en_US
dc.subject nanotechnology en_US
dc.subject preeclampsia en_US
dc.subject immunoassay en_US
dc.subject diagnosis en_US
dc.title Nanotechnology Enhanced Immunoassay for Preeclampsia en_US
dc.type Thesis en
thesis.degree.name Master of Science in Biology en_US
thesis.degree.level Master's en
thesis.degree.discipline Biology en
thesis.degree.grantor George Mason University en


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search MARS


Browse

My Account

Statistics